Output |
12V 0-10A |
24V 0-5A |
48V 0-2.5A |
Error |
±2% |
±1% |
±1% |
Output power |
120W |
120W |
120W |
Ripple & Noise (max.) |
80mVp-p |
80mVp-p |
100mVp-p |
Efficiency |
80% |
84% |
85% |
AC input voltage range |
88~132VAC / 176~264VAC selectable by switch 47~63HZ 248~370VDC |
||
Input current |
2.6A/115V 1.6A/230V |
||
AC Inrush current |
Cold-start current 20A/115V 40A/230V |
||
Leakage current |
<3.5mA/240VAC |
||
DC adjustable range |
±10% rated output voltage |
||
Overload protection |
105%-150% cut off the output, auto-recovery |
||
Over-voltage protection |
121%-142% cut off the output, auto-recovery |
||
Setup, rise time |
500ms, 70ms/230VAC 500ms, 70ms/115VAC at full load |
||
Hold time |
36ms/230VAC 32ms/115VAC at full load |
||
Withstand voltage |
I/P-O/P:3KvAC I/P-FG:1.5KvAC O/P-FG:0.5KVAC |
||
Isolation resistance |
I/P-O/P, I/P-FG, O/P-FG:100M Ohms/500VDC |
||
Working temperature and humidity |
-10°C~+60°C |
||
Temp. coefficient |
±0.03%/ºC (0 ~ 50ºC) |
||
Overall dimension |
65.5X125.2X100mm (W*H*D) |
||
Weight |
0.8kgS |
||
Note |
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25°C of ambient temperature. |